Tuesday, July 9, 2013
Networking in VIO Server
# mktcpip -hostname vios1 -inetaddr 192.168.10.55 -interface en0 -netmask 255.255.255.0 -gateway 192.168.10.1 -nsrvdomain mydomain.com -start
To list stored tcpip configuration:
# lstcpip -stored
To list ethernet adapters on the server:
# lstcpip -adapters
To show system hostname:
# lstcpip -hostname
To show dns servers:
# lstcpip -namesrv
To display routing table:
# lstcpip -routtable
To display routing table in numbers:
# lstcpip -num -routtable
To list all open inet sockets:
# lstcpip –sockets –family inet
To show the state of all configured network interfaces:
# lstcpip –state
To flush (remove) all tcpip settings:
# rmtcpip -all
To unconfigure a network interface:
# rmtcpip -interface en0
To clean up routing table:
# rmtcpip –f -routing
To remove DNS information:
# rmcpip –namesrv
To unconfigure tcpip information on en0 during next reboot:
# rmtcpip –f –interface en0 -nextboot
To add an entry to /etc/hosts:
# hostmap -addr 192.168.10.34 -host alpha
To list the contents of hosts file:
# hostmap -ls
To remove a specific entry on hosts files:
# hostmap -rm 192.168.10.34
To enable / start all network services:
# startnetsvc ALL
To disable / stop all network services:
# stopnetsvc ALL
To enable telnet on a VIO Server:
# startnetsvc telnet
To enable ftp on a VIO ServerL
# startnetsvc ftp
To enable ldap daemon:
# startnetsvc ldap
To enable xntpd:
# startnetsvc xntpd
To enable cimserver:
# startnetsvc cimserver
To send CLI tracing info to system log:
# startnetsvc tracelog
To send system error log to the system log:
# startnetsvc errorlog
To list the start of ftp daemon:
# lsnetsvc ftp
To add a domain name entry:
# cfgnamesrv -add -dname abc.aus.century.com
To add a name server entry:
# cfgnamesrv –add -ipaddr 192.9.201.1
To list all resolv.conf entries:
# cfgnamesrv -ls
To display statistics on a network interface:
# entstat en0
To reset statistics on a network interface:
# entstat –reset ent0
To trace a route:
# traceroute nis.nsf.net
Virtual Optical Device, Virtual Optical Drive and Virtual Media Library
# mkrep -sp rootvg -size 10G
Above command will create a filesystem called /var/vio/VMLibrary.
2. To create an iso from from AIX DVD:
# dd if=/dev/cd0 of=/cg/AIX61-1.iso bs=1m
You can copy the iso file to /var/vio/VMLibrary.
3. To list the contents of virtual media repository:
$ lsrep
Size(mb) Free(mb) Parent Pool Parent Size Parent Free
10198 5828 rootvg 139776 110592
Name File Size Optical Access
AIX61_1.iso 3679 vtopt0 rw
AIX61_2.iso 691 None rw
4. To create a Virtual Optical device :
# mkvdev -fbo -vadapter vhost0
5. To create a virtual optical media from a downloaded ISO image:
# mkvopt -ro -name aix61 -file /home/padmin/aix61.iso
6. To remove a virtual optical media:
# rmvopt -name aix61
7. To list all the virtual optical devices:
# lsvopt
8. To load the virtual optical media on a virtual optical device:
# loadopt -vtd vtopt0 -disk linux
9. To load an ISO file on a virtual optical device:
# loadopt -vtd vtopt0 -disk AIX61_1.iso
10. To check if the ISO was loaded correctly:
# lsmap -vadapter vhost0
11. To unload the virtual media from virtual optical device:
# unloadopt -vtd vtopt0
12. To force remove the virtual media:
# unloadopt -vtd vtopt0 -release
Friday, January 18, 2013
Backup on Virtual I/O Server
You can backup the structure of any volume group so that the configuration data will be stored under /tmp/vgdata. This will be automatically done if you run backupios (and even the configuration data will be automatically backed up).
Here are some commands.
To backup the structure of datavg :
# savevgstruct datavg
To display a list of saved volume groups
# restorevgstruct -ls
To restore the structure of datavg on 2 available disks :
# restorevgstruct -vg datavg hdisk2 hdisk3
BACKUP OF USER-DEFINED VIRTUAL DEVICES :
You can take a backup of all the user-defined virtual devices using the viobr command. But it requires minimum VIOS level 2.1.2.0. Backup file includes logical devices like storage pools, SEA, virtual server SCSI/FC/Ethernet adapters, device attributes for disks, optical devices, tape devices, LHEA, ethernet devices/interfaces.
Here are some commands
To take a backup of user-defined virutal devices in an XML file :
# viosbr -backup -file filename
To view the backup information :
# viosbr -view -file filename
To restore the virtual device configuration :
# viosbr -restore -file filename
To validate the backup file :
# viosbr -restore -validate -file filename
BACKUP OF VO SERVER :
To perform backup on a tape media :
# backupios -tape /dev/rmt0
To perform backup on a DVD media :
# backupios -cd /dev/cd0 -udf
To perform backup on a DVD-RAM disk :
# backupios -cd /dev/cd0 -udf -accept
To take backup on a file (Creates a file called nim_resources.tar) :
# backupios -file /mnt
To perform mksysb backup :
# backupios -file /mnt/vioserver1.mksysb -mksysb
How to update Virtual I/O Server ?
1. Shutdown the VIO clients. This would not be required in case of dual VIO setup.
2. Apply the update using the below command (you have to use the proper syntax)
# updateios
3. Reboot the Virtual I/O server
# shutdown -restart
4. Once the server comes back online, login and check the OS level
# ioslevel
5. After few weeks, you may have to commit the applied filesets
# updateios -commit
Here are the various ways of updating a Virtual I/O server
To update Virtual I/O server from a local directory :
# updateios -dev /tmp/viopack -install -accept
To update Virtual I/O servers from remote filesystem :
# mount NFS-server:/share-name /mnt
# updateios -dev /mnt -install -accept
To update Virtual I/O server from an optical drive :
# updateios -dev /dev/cd0 -install -accept
To commit all the uncommited filesets and then to update Virtual I/O server from an optical drive :
# updateios -f -dev /dev/cd0 -install -accept
Now let us look at the various uses of updateios command.
To commit all the applied filesets :
# udpateios -commit
To clean up after an interrupted installation :
# updateios -cleanup
To reject all the applied (uncommited) filesets :
# updateios -reject
To remove a fileststem from Virtual I/O server :
# updateios -remove fileset-name
Thursday, January 17, 2013
Virtual Ethernet - PowerVM
To list all the adapters :
# lsdev -type adapter
To list all the virtual adapters :
# lsdev -virtual
To list the configuration of a Ethernet adapter (including its MAC Address) :
# lscfg -l ent3
To list all the slots (Physical and Virtual) along with the devices :
# lsdev -slots
To create a SEA using the physical adapter (ent0), virtual adapter (ent2), PVID as 1 :
# mkvdev -sea ent0 -vadapter ent2 -default ent2 -defaultid 1
To create a SEA using the physical adapter (ent0), virtual adapter (ent2), PVID as 1, control channel (ent4) :
# mkvdev -sea ent0 -vadapter ent2 -default ent2 -defaultid 1 -attr ha_mode=auto ctl_chan=ent4
To identify the speed and duplex on a physical adapter :
# lsdev -dev ent0 -att | grep media_speed
To set the speed and duplex on a physical adapter :
# chdev -dev ent0 -attr media_speed=100_Full_Duplex
To remove the current tcpip/ip configuration :
# rmtcpip -all
To configure the IP address on a network interface :
# mktcpip -hostname vios1 -inetaddr 192.168.2.1 -interface ent3 -netmask 255.255.255.0 -gateway 192.168.2.1
To list the IP table :
# lstcpip -num -state
To list the routing table :
# lstcpip -routtable
To list the Physical/Virtual/Shared Ethernet Adapter mapping :
# lsmap -all -net
To identify the port VLAN ID of a virtual adapter :
# entstat -all ent2 | grep "Port VLAN ID"
To identify the port VLAN ID of a virtual adapter :
# entstat -all ent2 | grep "Switch ID"
To identify the Control Channel of a SEA :
# entstat -all ent5 | grep "Control Channel"
To identify the priority of a SEA :
# entstat -all ent5 | grep "Priority"
Commands for AIX Partition :
To identify the VLAN ID :
# entstat -d ent0 | grep ID
To identify the MAC Address :
# entstat -d ent0 | grep Address
Virtual SCSI - PowerVM
To view the current reserve policy of a disk :
# lsdev -dev hdisk2 -attr reserve_policy
To set the reservice policy of a disk :
# chdev -dev hdisk2 -attr reserve_policy=no_reserve -P
To view the current values of all the attribtues of a FC adapter :
# lsdev -dev fcs0 -attr
To modify the attributes of a FC adapter :
# chdev -dev fcs0 -attr fc_err_recov=fast_fail dyntrk=yes -P
To map a disk to a Virtual Server SCSI adapter :
# mkvdev -vdev hdisk2 -vadapter vhost0 -dev lpar1_vtd
Note: "-dev lpar1_vtd" is an option to specify the VTD name.
If not specified, it would take a default name.
To unmap a disk fro a Virtual Server SCSI adapter (Technically removing a VTD device) :
# rmvdev -vtd lpar1_vtd
To list all the backing device and Virtual Server SCSI adapter mapping :
# lsmap -all
To list all the backing devices mapped to a Virtual Server SCSI adapter :
# lsmap -vadapter vhost0
Commands for AIX sever :
To list the atttributes of a virtual disk :
# lsattr -El hdisk0
To set the necessary attributes of a virtual disk :
# chdev -l hdisk0 -a hcheck_mode=nonactive hcheck_interval=20 algorithm=fail_over
To list all the paths for the virtual disks :
# lspath
To list the parent device of a virtual disk :
# lsparent -CH -l hdisk1
To display more details for virtual disks :
# lspath -H -F "status name parent path_id connection"
N-Port Id Virtualization (NPIV) - PowerVM
1 Power feature (actually an industry standard) for virtualizing a phyiscal fibre channel port.
2. It allows multiple LPARs to share a physical fibre channel HBA.
3. Each logical HBA on the LPARs with have their own WWPN address (given in pairs; second WWPN is used for LPM) which can be used for SAN zoning.
4. Each physical HBA port can support upto 64 virtual ports.
5. Compatible with Live Partition Mobility.
NPIV Requirements :
- POWER6 or later
- FC 5735 PCI 8GB FC adapter (it comes with 2 ports)
- VIOS 2.1 or later
- HMC 7.3.4 or later
- OS
-- AIX 5.3 TL09 SP 2
-- AIX 6.1 TL02 SP2
-- AIX 7.1 TLxx SPx
-- SLES 10 SP2
-- RHEL 4.7 or later
You also need to have a NPIV capable SAN switch. So first of all check with your storage team before procuring NPIV capable servers.
How to create the Virtual adapters for the VIO and the LPARs ?
You should create the virtual FC adapters for the VIO and the LPARs by logging onto HMC as like we do the VSCSI adapters.
How to configure SAN Zoning ?
SAN zoning should be based on the WWPN from client's Virtual FC adapter and NOT the VIOS server adapters. You need to be very careful with this. Otherwise you would not see the SAN LUNs fron the partition.
Here are some commands that can be used on the VIO server.
To map a Physical HBA port to a virtual FC adapter :
# vfcmap -vadapter vfchost0 -fcp fcs0
To unmap a Physical HBA port and a virtual FC adapter :
# vfcmap -vadapter vfchost0 -fcp
To list the mapping between a specific virtual and physical FC adapters :
# lsmap -npiv -vadapter vfchost0
To list the mapping between all Virtual and Physical FC adapters :
# lsmap -all -npiv
To list the available NPIV capable ports :
# lsnports
To list the Virtual FC adapter details :
# lsdev -dev vfchost0
To list the NPIV physical FC adapter details :
# lsdev -dev fcs0
To monitor I/O traffic on a virtual FChost (server side virtual adapter) :
# viostat -adapter vfchost1
Here are some commands that can be used on HMC.
To list the virtual FC adapters on all the lpars on a managed system :
# lshwres --rsubtype fc -m managed-system --level lpar -r virtualio
To list the WWPN and to check whether its active or not on all the LPARs in a managed system :
# lsnportlogin -m managed-system --filter "profile-names=normal"
Here are some commands that can be used on LPAR level.
To view the WWPN of a virtual FC adatper :
# lscfg -vpl fcs0 | grep Net
To view t he statistics on a virtual FC adapter (client) :
# fcstat fcs0
Sometimes you may need to set a specific WWPN on the virtual adapters on the client.
You can use the below commands (in HMC) during that scenario.
To list the Current Profile details:
hscroot@hmc1:~> lssyscfg -r prof -m sys709 --filter "lpar_ids=30,"profile_names=Normal""
name=Normal,lpar_name=lpar01,lpar_id=30,lpar_env=aixlinux,all_resources=0,min_mem=1024,desired_mem=1536,max_mem=2048,min_num_huge_pages=0,desired_num_huge_pages=0,max_num_huge_pages=0,mem_mode=ded,mem_expansion=0.0,hpt_ratio=1:64,proc_mode=shared,min_proc_units=0.1,desired_proc_units=0.2,max_proc_units=1.0,min_procs=1,desired_procs=1,max_procs=3,sharing_mode=uncap,uncap_weight=128,shared_proc_pool_id=0,shared_proc_pool_name=DefaultPool,affinity_group_id=none,io_slots=none,lpar_io_pool_ids=none,max_virtual_slots=50,"virtual_serial_adapters=0/server/1/any//any/1,1/server/1/any//any/1","virtual_scsi_adapters=20/client/2/sys506_vios2/4/1,10/client/1/sys506_vios1/4/1",virtual_eth_adapters=2/0/2//0/1/ETHERNET0//all/0,vtpm_adapters=none,"virtual_fc_adapters=""29/client/1/sys709_vios1/29/c506000000000009,c506000000000010/0"",""30/client/2/sys506_vios2/30/c506000000000011,c506000000000012/1""",hca_adapters=none,boot_mode=norm,conn_monitoring=1,auto_start=0,power_ctrl_lpar_ids=none,work_group_id=none,redundant_err_path_reporting=0,bsr_arrays=0,lhea_logical_ports=none,lhea_capabilities=none,lpar_proc_compat_mode=default,electronic_err_reporting=null
To change the WWPN of the Virtual FC adapters (at slot numbers 29 and 30) on a LPAR Profile:
hscroot@hmc1:~> chsyscfg -r prof -m sys709 -i name=Normal, lpar_name=lpar01, \"virtual_fc_adapters=\"\"29/client/1/sys709_vios1/29/c506000000000009,c506000000000010/0\"\",\"\"30/client/2/sys709_vios2/30/c506000000000011,c506000000000012/1\"\"\"
Integrated Virtual Ethernet
It is the collection of hardware, software ad hypervisor feature that provides the hardware-based virtualization capabilities on POWER machines.
It is available on POWER6 and later machines.
What is Host Ethernet Adapter ?
It is the majoy hardware component of the IVE.
It is the Ethernet Adapter built on the Power chip that provides IVE feature on POWER machines.
There are 3 types of HEA's available
Type-1 is a 2-Port 1GB Adapter (FC 5636) - Copper, 16 MAC addresses, one port group
Type-2 is a 2-Port 10GB Adapter (FC 5637) - Optical - 32 MAC addresses, two port groups
Type-3 is a 4-Port 1GB Adapter (FC 5639) - Copper, 32 MAC addresses, two port groups

What is an IVE port?
It is the physical port on the HEA which can be logically presented to LPARs.
Basically IVE ports are part of port groups.
A port group supports a maximum or 16 logical ports a.k.a Logical Host Ethernet Adapter (Which can be assigned to LPARs).
On a Copper based HEA, 2 physical ports belongs to a port group whereas on a Optical adapters its 1 port per port group.
-> Type-1 adapter can support 16 logical ports (ie., can be assigned to 16 lpars).
-> Type-2 adapter can support 16+16 ie., 32 logical ports.
->Type-3 adapter can support 16+16 ie., 32 logical ports.
- While ordering a POWER machine, you need to choose the type of HVE Otherwise you will receive a Type-1 adapter which is the default.
- IVE feature is installed during manufacturing.
- IVE is not a hot-swappable or hot-pluggable feature.
- IVE must be serviced only by an IBM Service Engineer.
- All the logical ports in a port group can talk to each other without external connectivity, which means all the LPARs on a port group are connected to each other via Layer2 switch on IVE.
- You can assign the logical ports to LPARs only thru HMC.
MCS :
- Multiple Core Scaling (MCS) is a parameter that allows multiple receive and transmit queues (QP) to be supported in each LPAR.
- It is defined at the port group level.
- Default value is 4.
- Depending on the MCS value, the maximum number of logical ports per port group varies.
- MCS value can be set only thru HMC.
IVE Configuration :
An LPAR can use only one logical port per physical port.
While activating an LPAR containing IVE logical ports, the resource is required for activation.
Whereas during DLPAR operation, the IVE logical port is considered as a desired resource.
If you want to add additional VLANS to an existing configured port, you must remove and add the port again with required VLAN IDs.
What you see on LPAR ?
After assigning a logical port to a LPAR, you have to run cfgmgr to see the below devices
-> lhea0 - Logical Host Ethernet Adapter
-> ent0 - Logical Host Ethernet Port
-> en0 and et0 - Logical interfaces
What is Promiscuous mode ?
You can set a physical port (on a HVE thru HMC) to promiscous mode.
If set, that particular port will be reserved for an LPAR. So other LPARs can't see this port.
This is mostly used whilst using VIO on a POWER machine or while configuring a port for a partition running AIX V5.2.
You can refer the URL to get an idea on how to set promiscuous mode in HMC.
What are the OS requirements ?
# IBM AIX 5L™ Version 5.3
– Service Pack 5300-06-02.
– Packaging APAR for this package is IY99738.
– IVE fileset devices.chrp.IBM.lhea.rte must be at level 5.3.0.2 or later.
# IBM AIX 5L Version 5.2
– Service Pack 5200-10-02.
– Packaging APAR for this package is IZ00822.
– IVE fileset devices.chrp.IBM.lhea.rte must be at level 5.2.0.107 or later.
# Red Hat RHEL 4.5 or later
# SuSE SLES 10 SP1 or later
Here are some commands you may use at the LPAR level to find additional details.
To identify the logical port number :
# entstat -d ent0 | grep "Logical Port Number"
To identify the relation between lheax and entx devices :
#lsslot -c slot | grep -i hea
Slot Description Device(s)
HEA 1 Logical I/O Slot lhea0 ent0 ent1
Here are some commands you may use at HMC shell prompt.
To list all the available adapters and their ports on a managed system :
# lshwres -r hea --rsubtype phys --level sys -m machine_name
To view the port groups on a managed system :
# lshwres -r hea --rsubtype phys --level port_group -m machine_name
To view the physical ports on a managed system :
# lshwres -r hea --rsubtype phys --level port -m machine_name
To view all the logical ports on a managed system :
# lshwres -r hea --rsubtype logical --level sys -m machine_name
To list port configuration configured for an LPAR :
# lshwres -r hea --rsubtype logical --level port -m machine_name --filter lpar_names=lpar01
PowerVM
Licensed software/firmware feature which enables IBM virtualization technology on IBM POWER systems.
Available on Power5, Power6 and Power7 Systems
Allows AIX 5L V5.3 or later and Linux LPARs to run without physical adapters.
It is available in the following 3 editions
1. IBM PowerVM Express Edition
2. IBM PowerVM Standard Edition
3. IBM PowerVM Enterprise Edition
Virtual I/O server is available as part of the PowerVM Editions (formarley known as Advanced POWER Virtualization) feature.
Virtual I/O Server facilitates:
1. Sharing of physical resources between LPARs on the system.
2. Creating LPARS without requiring additional physical resources like Network Adapter, HBA, SCSI Adapter.
3. Creating more LPARs than there are I/O slots or physical devices.
4. Maximizing use of phyiscal resources on the system
Friday, November 13, 2009
Tips on VIrtualization and Micropartitioning
a. Installation from CD
b. NIM Based installation
2. What is the maximum # of virtual processor per partition (lpar) ?
64 Virtual Processors
3. What is the maximum # of logical processor supported by AIX Operating System ?
128 Logical Processors
4. What are the different types of processor sharing modes ?
Capped or Uncapped modes
5. What are the different types of I/O virtualization that can be implemented in a p5 server ?
a. Virtual Ethernet
b. Shared Ethernet Adapters
c. Shared Fibre Channel Adapters
d. Virtual Disks
6. What is the range for variable capacity weight ?
0 to 255 is the range for the variable capacity weight.
128 is the default weight for uncapped partitions.
Weight 0 is equivalent to capped mode.
7. What is the LMB for Power 4 and Power 5 machines ?
Power 4 - 256 MB Logical Memory Block
Power 5 - 16 MB LMB
LMB is the minimum memory block that can allocatable to an LPAR.
8. What is the minimum allocatable processing unit for an lpar ?
Initial assignment is a minimum of 0.10 (1/10th) processing unit.
Increments can be made at a minimum of 0.01 (1/100th) proccessing unit.
9. How can we calculate hypervisor overhead for an lpar ?
It can be calculated by dividing the maximum memory setting by 64 and rounding up to the nearest logical memory block size.
10. TIP :
You can have maximum of 256 VIO slots per partition
11. TIP :
In VIO Server, you can have maximum of 65535 virtual I/O slots
12. TIP :
You can have maximum of 256 Virtual Ethernet Adapters per partition
13. TIP :
You can have 254 partitions or 10 * # processors per power machine
14.
Under construction ...
Sunday, November 4, 2007
Virtual I/O Server - Some Commands
Initialize the LPAR Configuration :
# mkgencfg -o init
[OS] Software Management :
To display VIO Server level:
# ioslevel
To update the IOS software:
# updateios –dev /update -
To installs a new filesets (mainly used for TL updates):
# updateios –dev /cd0 -install -accept
To commit all applied :
# updateios –commit
To rejects all uncommitted updates :
# updateios –reject
To clean all incomplete pieces of the previous installation :
# updateios –clean
To remove a fileset :
# updateios –remove fileset_name
To take the OS backup in a CD ROM :
# backupios –cd /dev/cd1 -cdformat
To take the OS backup in a DVD-RAM :
# backupios –cd /dev/cd1 -udf
To take the OS backup in a tape drive :
# backupios –tape /dev/rmt0
Just verifies the backup available in a tape :
# backupios –tape /dev/rmt0 -verify
Generates backup to a file. No user VGs are -nosvg back’d up :
# backupios –file /opt/file1
To display the underlying AIX OS version :
# oem_platform_level
To open a non-restricted root shell :
# oem_setup_env
This shell is used mainly for the installation of vendor software such as device drivers.
Remote Management :
To enable remote_management using NIM master :
# remote_management nim1
To disable remote management :
# remote_management –disable
License Management:
To display the current license :
# license –view
To accept the license :
# license –accept
To view if the license has been accepted :
# license
Software Management:
To list all the installed software :
# lssw
To list all the installed software and their history
# lssw –hist
Management of Virtual Terminals:
To open a virtual terminal for partition with id 2 :
# mkvt –id
To close a virtual terminal for a partition with id 2 :
Device Management:
To change the attribute of a device permanently.
# chdev -dev scsi0 -attr id=6 -perm
Sometimes it reboots the system if perm is used
To disable the path between hdisk1 and scsi0 :
# chpath -dev hdisk1 -pdev scsi0 -op disable
To configures the devices in the VIO server :
# cfgdev
To configures the devices attached to scsi0 adapter :
To unconfigure the cd-rom device :
# rmdev –dev cd0
To unconfigure scsi adapter and its child devices :
# rmdev –recursive –dev scsi1
To unconfigures the children of pci1 but not the PCI bus pci1 :
# rmdev –pdev pci1
Management of Virtual/Shared Devices:
To create a virtual target device that maps lv20 as a virtual disk for a client partition hosted by the vhost0 virtual server adapter :
# mkvdev -vdev lv20 -vadapter vhost0
Same as above except here hdisk is used instead of a logical volume :
# mkvdev -vdev hdisk6 -vadapter vhost2
To create a SEA that maps the physical Ethernet adapter ent4 as a virtual adapter for the client
partitions served by the virtual Ethernet adapters ent6 and ent7, using ent6 as the default adapter and 8 as the default id :
# mkvdev -sea ent4 -vadapter ent6,ent7 -default ent6 -defaultid 8
To remove a virtual target device vtscsi9 along with its backing lv :
# rmvdev –vdev vtscsi9 –
To remove all virtual target device associated with backing device lv001 :
# rmvdev –vdev lv001
To remove a specific virtual target device :
# rmvdev –vtd vtscsi10
List Device Mapping:
To list all virtual target devices and backing devices mapped to virtual server adapter vhost2 :
# lsmap -vadapter vhost2
To list SEA and physical device mapped to virtual Ethernet Adapter ent4 :
# lsmap -vadapter ent4 –net
# lsmap -all -type lv
To list all network mapping :
# lsmap –all –net
How to list Devices :
To display all the devices :
# lsdev
To display all the virtual devices :
# lsdev –virtual
To display all the virtual adapters :
# lsdev –type adapter –virtual
To display all the slots :
# lsdev –slot s
To display all the adapters :
# lsdev –type adapter
Few other device types: disk, lv, optical, tape, tty
To list all physical Ethernet adapters and Etherchannel available for creating a SEA :
# lsdev –type ent4sea
To list all virtual Ethernet adapters available for creating a SEA :
# lsdev –type ven4sea
To list all adapters over which ip address can be configured :
# lsdev –type ent4ip
To display parent device of a device :
# lsdev –dev hdisk0 –
To list disks names and physical location alone :
# lsdev -type disk -field name physloc
Logical Volume Manager :
Volume Group
To create a vg on hdisk1 :
# mkvg -vg newvg hdisk1
To drain I/O's for a vg and suspends future I/O's :
# chvg -suspend vg03
To resume normal I/O operations for a vg :
# chvg -resume vg03
Unlock a VG if left in a locked state by abnormal termination of another lvm operation :
# chvg -unlock vg03
To add a physical volume to a volume group :
# extendvg vg3 hdisk3
To remove a PV from a VG :
# reducevg vg01 hdisk1
To remove a PV and all residing LVs from a VG with no confirmation :
# reducevg –rmlv –f vg01
To activate a vg :
# activatevg vg03
To deactivate a vg :
# deactivatevg vg03
To mirror the VIO Server’s rootvg to hdisk4 and reboots VIO Server :
# mirrorios –force hdisk4
To mirror the VIO Server’s rootvg to hdisk4 but don’t reboot the server :
# mirrorios –defer hdisk4
To remove the rootvg mirror from hdisk4 :
# unmirrorios hdisk4
To import a VG from hdisk07 :
# importvg –vg vg001 hdisk07
To export a VG :
# exportvg vg3
Note: Volume Group containing a paging space can’t be exported
To sync a VG :
# syncvg –vg vg01
To sync a LV :
# syncvg –lv lv001
To sync a PV :
# syncvg –pv hdisk4 hdisk5
To redefine a VG based on the VGDA from hdisk04 :
# redefvg –dev hdisk04
Logical Volume :
To create a logical volume of size 1MB in vg01 :
# mklv –lv lv001 vg01 1M hdisk1
To create a logical volume with mirror in place in vg01 of size 1GB :
# mklv –mirror vg01 1G
To extend an LV by 3MB :
# extendlv lv01 3M
To extend an LV by 1GB with space taken from hdisk5 :
# extendlv lv01 1G hdisk5
To remove a logical volume :
# rmlv lv05
To display the properties of a logical volume :
# lslv lv03
To display info about LV by Physical volume :
# lslv –pv lv03
To display LVs that can be used as backing devices :
# lslv –free
To make a copy for lv01 in hdisk03 :
# mklvcopy lv01 hdisk03
To remove lv01’s copy from hdisk03 :
# rmlvcopy lv01 hdisk03
To copy the contents of lv01 to lv02 :
# cplv lv01 lv02
To copy the contents of lv01 to a new lv in vg01 :
# cplv –vg vg01 lv01
To change the name of oldlv to newlv :
# chlv –lv newlv oldlv
Physical Volume
To display all physical volumes in the system :
# lspv
To display the status and characteristics of hdisk03 :
# lspv hdisk03
To list all the available PVs used as virtual SCSI backing devices :
# lspv –avail
To list PVs that can be used as virtual SCSI backing devices and are not currently a backing device :
To move physical partitions from hdisk1 to hdisk2 :
# migratepv hdisk1 hdisk2
To move physical partitions in lv01 from hdisk1 to hdisk2 :
Storage Pool Management:
To create storage pool “client_data” using hdisk3 hdisk4 hdisk3 and hdisk4 :
# mksp -f client_data
To set client_data storage pool as default :
To list all storage pools :
# lssp
To list the default storage pool :
# lssp –default
To list the backing device in rootvg storage pool :
To attach a storage from a storage pool to a Virtual SCSI adapter:
To removes storage from a Virtual SCSI adapter, and removes the backing device :
To remove storage from a Virtual SCSI adapter, And makes sure backing device is not deleted :
# rmbdsp –bd lv001 -savebd
To removes storage from a Virtual SCSI adapter, and removes the backing device :
To removes storage from a Virtual SCSI adapter. and makes sure backing device is not deleted :
# rmbdsp –vtd vtscsi8 -savebd
Network Configuration :
TCP/IP Configation:
To configure tcpip on a network interface :
# mktcpip -hostname sys01vio2 -inetaddr 9.47.90.113 -interface en2 -netmask 255.255.255.0 -gateway 9.47.90.1 -nsrvdomain yahoo.com -start
-
To display the stored tcp/ip configuration in the system :
# lstcpip –stored
To display ethernet adapters on the system :
To display the system hostname :
# lstcpip –hostname
To display DNS name servers in search order and domain name :
# lstcpip –namesrv
To display the routing table :
# lstcpip –routtable
To display routing table in numeric output instead of hostname :
To display all the open inet sockets :
To display the status of all configured interfaces :
# lstcpip –state
To remove all TCP/IP configuration :
# rmtcpip –all
To unconfigure tcpip in en0:
# rmtcpip –interface en0
To cleanup static routing table :
# rmtcpip –f -routing
To remove IP information from en0 after reboot :
Managing IP address-to-host name Mapping Entries:
To add IP address-to-host name mapping entry :
# hostmap -addr 192.100.1.7 -host alpha
To list all IP address-to-host name mapping entries :
# hostmap –ls
To delete the IP address-to-host name mapping entry :
# hostmap-rm 192.100.1.7
Managing Network Services:
To enable all the network services :
# startnetsvc ALL
To enable the telnet daemon :
# startnetsvc telnet
To enable the ftp daemon :
To enable the ssh daemon :
To enable the ldap daemon :
# startnetsvc ldap
To enable the cimserver daemon :
To enable the xntpd daemon :
To send CLI tracing details to the system log :
# startnetsvc tracelog
To send system error to the system log :
# startnetsvc errorlog
To disable all the network services :
# stopnetsvc ALL
To disable the telnet daemon :
# stopnetsvc telnet
To disable the ftp daemon :
# stopnetsvc ftp
To disable the ssh daemon :
# stopnetsvc ssh
To disable the ldap daemon :
# stopnetsvc ldap
To disable the cimserver daemon :
# stopnetsvc cimserver
To disable the xntpd daemon :
stopnetsvc xntpd
To stop sending CLI tracing details to system log :
# stopnetsvc tracelog
To stop sending system error log to the system log :
# stopnetsvc errorlog -
To display the status of ftp network service :
# lsnetsvc ftp
Managing DNS, Domain and Search
To add a domain entry :
# cfgnamesrv -add -dname abc.aus.century.com
To add a name server entry :
# cfgnamesrv –add -ipaddr 192.9.201.1
To display all the DNS entries :
# cfgnamesrv -ls
Network Tuning Parameters:
To display the maximum size of the mbuf pool :
# optimizenet –get thewall
To set a machine as internet work router over TCP/IP networks :
# optimizenet –set ipforwarding=1
To display information on udp_recvspace :
# optimizenet –h udp_recvspace
Network Monitoring:
To display all the statistics, including the device- specific statistics :
# entstat ent0
To reset all the statistics back to their initial values :
To display the route to a particular host :
System Monitoring :
To display the summary of current system activity :
To display the system statistics :
# topas
System Management Commands:
To halt the operating system :
# shutdown
To halt the operating system forcibly :
# shutdown –force
To reboot the vio server :
# shutdown –restart
To invalidate the boot list for service mode :
# bootlist -mode service –rm
To display the boot list for service mode :
# bootlist -mode service –ls
To set the boot list for normal mode :
# bootlist –more normal hdisk0
To display the complete detailed error report :
# errlog –ls
To remove all the error log entries :
# errlog –rm 0
To remove the error log entries older than 5 days :
# errlog –rm 5
To change the system date and time :
# chdate -day 12 -month 10 -year 2004 -hour 16 -minute 30
To change the language for the entire system to French Canadian :
# chlang -lang fr_CA
To display available languages :
# chlang –ls
To perform hardware problem determination and maintenance :
# diagmenu
To generate report on microcode levels of all the devices :
To display the vpd survey of the partition :
# invscout –vpd
To append the current MOTD [Message Of The Day] :
# motd –append “Message”
To overwrite MOTD :
# motd –overwrite -file filename
To do the initial configuration of VIO Server :
# cfgassist
It is like configuration assitant in AIX.
To do filesystem scan :
# fsck /dev/lv01
To display exported (nfs) directories on a remote server :
# showmount hostname
To start system dump on the primary device :
# startsysdump
To display continuous disk report on disk1 at 2sec interval :
# viostat -disk disk1 2
To display adapter throughput reports :
# viostat –adapter
To display system and adapter throughput reports :
# viostat –sys –adapter
To gather system info and to store it in the floppy disk :
# snap -general -dev /dev/rfd0
To display microcode levels of all devices :
# lsfware –all
Managing Agents:
To start an agent : # startsvc agent_name
To stop an agent: # stopsvc agent_name
To display an agent's configuration information :
# lssvc agent_name
To display all the available agents :
# lssvc
To display the attributes associated with ITSM_base agent :
# cfgsvc –ls ITM_base
To display the ITM_base agent ssh public key :
# cfgsvc -key ITM_base
User Management:
To create a user :
# mkuser
To change an attribute of a user :
# chuser
To display the properties of a user :
# lsuser
To remove a user from the system :
# rmuser
To set/reset password for a user :
# passwd
Security Commands:
To display all failed logins :
# lsfailedlogin
To display the contents of global command log :
# lsgcl
To displays high system settings :
# viosecure -level high
To apply all of the high system settings to the system :
# viosecure -level high –apply
To displays the current system settings :
# viosecure –view
To allow IP activity on the ftp-data, ftp, ssh, www, https, rmc, and cimon ports, and to deny other IP activity :
# viosecure –firewall on
To enable IP activity on all ports :
# viosecure –firewall off
To display the list of allowed ports :
# viosecure -firewall view